The Mecer inverters are fully compatible with the Hubble range of batteries.
The following field guide will assist with the correct battery settings you should use.
​
For further detailed information ensure you read the manual of the supplied battery regarding the setup and installation instructions.
mecer INVERTER SET UP

Model | Voltage | Bulk/Equalised (Vdc) | Float Voltage (Vdc) | Cutoff Voltage (Vdc) | Recommended Charge Amps | Max Discharge Current (A) |
---|---|---|---|---|---|---|
S SERIES | 12V | 14 | 14 | 12 | 30A | 100A |
X-100 | 48V | 52.8 | 52.8 | 44 | 30A | 100A |
X-101 | 48V | 53.8 | 53.8 | 44 | 30A | 100A |
X-200 | 36V | 41.5 | 41.5 | 34 | 30A | 100A |
AM-2 | 48V | 53.8 | 53.8 | 44 | 30A | 100A |
AM-3 | 48V | 53.8 | 53.8 | 44 | 20A | 50A |
AM-4 | 24V | 29 | 29 | 23.8 | 30A | 100A |
AM-5 | 48V | 55.2 | 55.2 | 47 | 30A | 100A |
AM-10 | 48V | 55.2 | 55.2 | 47 | 60A | 150A |
BLADE | 48V | 55.2 | 55.2 | 47 | 50A | 200A |
INVERTER SETTINGS
INVERTER example
HUBBLE DIP SWITCH SETTINGS FOR MULTIPLE BATTERY INSTALLATION
​
​For correct setup and communication each battery needs a unique serial address in order to communicate. If you are only using one battery in your setup, consider this the master battery and ensure you set it to address 1.
am-2

am-5 & AM-10

How do you setup multiple batteries?
See table above and check your product manual for a more detailed explanation. You will have to set dip switch settings per battery to give them a unique address. You also have to connect the included RJ45 battery link cables into the "Battery Link" port of each battery. Ensure your master battery dip switch 1 is on, 2,3,4 is OFF. Only the master battery CAN Bus will be enabled. You can then connect the Hubble Cloudlink into the CAN port of the master battery for communications to work.
​
​
Do I have to use the communication battery link cables if i dont want to monitor or have communications?
Yes